TraceAxis ConsoleIncident Ops
Current Workspace

Mission timeout after network disconnect

Telemetry dropped for 14 seconds during route update and mission state machine timed out.

Robot
AX-21
Site
Seattle Test Floor
Version
v0.9.13
Active frame
06:37
Primary Replay

Interactive incident stage

T + 06:37
Forward cameraWaypoint M-14
Planner recovery loop engages

The robot enters recovery mode, holds forward motion, and begins re-localization attempts.

Planner mode recovery
Event: Operator bookmark
Trace: mission_state
Control Trace

Commands and transitions

Replay Timeline

Scrub incident progression

Selected event 07:11
Signals

Telemetry synchronized to cursor

Cursor 06:37
Localization Confidence82
Sample aligned to selected frame
Battery Voltage51
Sample aligned to selected frame
Velocity Command0.8
Sample aligned to selected frame
Event Stream

Anomalies and transitions

Run Metadata
RobotAX-21
SiteSeattle Test Floor
Versionv0.9.13
Selected frame06:37
Cause: Network Disconnect
Status: resolved
Inspector

Pinned topics

Preview
{ pose_confidence: 0.51, covariance: 0.18 }
Summary

Root-cause hypothesis

Localization degraded after a moving forklift blocked landmark visibility near waypoint M-14. Planner fallback entered recovery, but pose confidence never recovered before the mission abort threshold.

Primary cause: landmark occlusion
Secondary risk: map shift near M-14
Autonomy Lead2026-04-22 19:58

Planner fallback triggered correctly, but localization confidence never recovered after forklift occlusion.

Perception Engineer2026-04-22 20:11

Need to check whether April map refresh shifted the aisle landmark geometry near waypoint M-14.