Incident summary

Capture the failure narrative, supporting evidence, and internal notes before sharing the incident.

Summary · inc_0422_docking · 2026-04-22 08:15

Docking abort after battery sag

highrobotAX-04siteLong Beach Labversionv0.9.14duration04m 49sfailureBattery Sag
Root-cause hypothesis

Voltage drop triggered a safety rollback during docking. Recovery succeeded on second attempt.

primarylandmark occlusionsecondarymap shift near M-14
Key moments
Notes
  • Autonomy Lead2026-04-22 19:58

    Planner fallback triggered correctly, but localization confidence never recovered after forklift occlusion.

  • Perception Engineer2026-04-22 20:11

    Need to check whether April map refresh shifted the aisle landmark geometry near waypoint M-14.

Bookmarks
  • Forklift enters lane· Ops Review369000ms
  • Pose drops below threshold· Autonomy Lead372000ms
  • Mission abort decision· Planner Team423000ms